Closed Circuit Cooling Tower
A tube-bundle heat exchanger inside the tower keeps the process fluid in a clean, sealed loop while spray water and air reject heat outside the coil. Closed circuit cooling towers protect water quality, cut scaling, save water in cold weather and extend the service life of critical equipment.

In a closed circuit cooling tower (also called a closed loop fluid cooler or evaporative fluid cooler), the process fluid never contacts ambient air. It flows inside a tube bundle while a separate spray-water loop wets the coil and induced air carries away the heat of evaporation. This indirect arrangement prevents contamination, scaling and oxygen ingress in the primary loop.
Stability: soft or treated water circulates in a sealed loop, so high-temperature scaling is avoided — protecting equipment such as induction furnaces from gradual overheating damage. Parameter setting and alarm systems keep the cooling process stable.
Water and energy savings: no excavation of a large basin is required and the unit can be relocated. At low ambient temperatures the spray system can be shut down for dry operation. Fan speed and spray volume are modulated with ambient conditions, so the fan and pump only run at the duty actually required.
Environmental performance: the sealed internal circuit protects circulating water, evaporation losses are small, and the risk of water-based bacteria around the tower is reduced. Corrosion-resistant metal construction typically delivers 8–10 years of service with proper maintenance. Our engineering team also provides winter freeze-protection strategies for both idle and part-load operation.
Key advantages
Clean process loop
Indirect coil heat exchange keeps the fluid sealed and uncontaminated.
Water saving
Spray water can be stopped in cold weather; no large basin required.
Energy saving
Fan and spray pump staged or modulated to ambient conditions.
Freeze protection
Sloped self-draining coil, air valve, compressed-air assisted drain-down.
Long service life
Corrosion-resistant metal construction, typically 8–10 years with proper care.
Specification & configuration
| Circuit | Closed circuit / indirect evaporative cooling (fluid cooler) |
|---|---|
| Heat exchanger | Tube coil bundle, sloped for complete self-drainage |
| Spray system | Independent spray-water loop with staged pump control |
| Airflow | Induced draft, top-mounted axial fans |
| Process fluid | Water, glycol solution, quench oil or other clean media |
| Capacity | Project-specific thermal selection — single module to multi-module banks |
| Options | Freeze-protection package, VFD, PLC / alarm panel, stainless coil, low-noise fans, plume abatement |
Typical applications
- Induction furnaces & heat treatment
- Data center and process glycol loops
- Air compressors & injection moulding
- Power electronics and welding equipment
- Chemical and mechanical processing
Product gallery
Tell us about your cooling duty
Share your flow rate, inlet / outlet water temperature and design wet-bulb temperature — we will size the right tower for you.
Talk to a cooling tower engineer
Technical selection, drawings and a quotation — usually within one business day.